Challenge

Intermittent network failures when communicating to the VMware host. The errors can vary but all have some variation of: 
“Error observed by underlying BIO: No such file or directoryDetail: 'SSL connect failed in tcp_connect()', endpoint:” 

Guest processing credentials test will also fail over VIX with this error, and you may get a pop up error bellow when editing the Vsphere host: 

User-added image

But on a second try it will continue.

Cause

Unsupported network configuration in VMware.  A vm kernel nic with Management is set on a port group no longer becomes eligible to have vms on it.  If a vmkernel port with management option is added to a network with vms attached you will see the following warning in VMware. 

User-added image

In Veeam we intermittently get the error “Error observed by underlying BIO: No such file or directoryDetail: 'SSL connect failed in tcp_connect()', endpoint:”,  however sometimes the jobs will work if retried enough times. 

Solution

Remove the Management vmkernel port from the vm network, or move the vms to a network without a management vmkernel port.
 
To submit feedback regarding this article, please click this link: Send Article Feedback
To report a typo on this page, highlight the typo with your mouse and press CTRL + Enter.

Spelling error in text

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Thank you!

Thank you!

Your feedback has been received and will be reviewed.

Oops! Something went wrong.

Please try again later.

You have selected too large block!

Please try select less.

KB Feedback/Suggestion

This form is only for KB Feedback/Suggestions, if you need help with the software open a support case

By submitting, you are agreeing to have your personal information managed in accordance with the terms of Veeam's Privacy Notice.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Verify your email to continue your product download
We've sent a verification code to:
  • Incorrect verification code. Please try again.
An email with a verification code was just sent to
Didn't receive the code? Click to resend in sec
Didn't receive the code? Click to resend
Thank you!

Thank you!

Your feedback has been received and will be reviewed.

error icon

Oops! Something went wrong.

Please try again later.