#1 Global Leader in Data Protection & Ransomware Recovery

iXsystems M-Series (ISCSI)

Veeam Ready - Repository
Alliance Partner:

iXsystems

Alliance Product:

TrueNAS M-Series

Program Category:

Veeam Ready - Repository

Category Description:

Verified backup storage that supports all Veeam backup and restore features.

Article ID:

150

Veeam Product(s):
  • Veeam Backup & Replication 12
Features and Attributes:
  • Backup Target - Disk ISCSI
Publication date:

2018-04-18

Last modified date:

2023-12-04

This Veeam Ready test was performed with storage having a configuration that includes SSD/Flash.  As such, this classification only applies to similar configurations in which the same amount or more SSD drives are used.  The use of non-SSD drives may negatively impact performance.

Product Details

Model number: TrueNAS M30
Storage Category: Software Defined Storage - Hybrid
Drive quantity, size, type:

  • 20 x 10 TB SAS HDD HUH721010AL4200
  • 1 x 3.84 TB SAS SSD XS3840SE70055

Storage configuration: 

  • 10 pairs of striped ZFS mirrors with a single SAS SSD for read caching
  • RAIDz mirror, 10 pairs, with 1 ZFS L2ARC cache drive on SSD

Firmware version: 23.10.0
Connection protocol and speed: 10 GbE iSCSI
Additional support: All models and configurations of TrueNAS M-Series with specifications equivalent or greater than the above

General product family overview:
TrueNAS is an Open Source storage operating system built on OpenZFS. The TrueNAS M-Series modular hardware architecture supports multiple applications with its hybrid flash and disk storage pools.
The TrueNAS M-30 is a 4U system with dual controllers.

Veeam Testing Configuration

Veeam Build Number: 12.0.0.1420 P20230718

Vendor recommended configuration

Vendor Settings:

  • Caching used: Yes
  • Read/write caching: Secondary ARC device acts as a read cache. ZFS uses ARC to cache recently and frequently accessed data. As new data is added to primary ARC the older data is moved to secondary ARC, which can be accessed faster than data off of the HDD array. In this test the 3.84TB SAS SSD was used as secondary ARC.
  • Networking: MTU=9000
  • Multipathing / link aggregation used: No
  • Array deduplication used in testing: No
  • Array compression used in testing: Yes

Couldn't find what you were looking for?

Below you can submit an idea for an article.
Report a typo on this page:

Please select a spelling error or a typo on this page with your mouse and press CTRL + Enter to report this mistake to us. Thank you!
Alliance Partner content request
By submitting, you are agreeing to have your personal information managed in accordance with the terms of Veeam's Privacy Notice.
By submitting, you are agreeing to receive information about Veeam products and events and to have your personal information managed in accordance with the terms of Veeam's Privacy Notice.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Verify your email to continue your product download
We've sent a verification code to:
  • Incorrect verification code. Please try again.
An email with a verification code was just sent to
Didn't receive the code? Click to resend in sec
Didn't receive the code? Click to resend

ty icon

Thank you!

We have received your request and our team will reach out to you shortly.

OK

error icon

Oops! Something went wrong.

Please try again later.

Spelling error in text

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Thank you!

Thank you!

Your feedback has been received and will be reviewed.

Oops! Something went wrong.

Please try again later.

You have selected too large block!

Please try select less.