Cisco Systems UCS C-Series
Alliance Partner: |
Cisco Systems |
Alliance Product: |
UCS C-series |
Program Category: |
Veeam Ready Repository - Primary Target |
Category Description: |
Solutions certified as a primary backup target. Passing all compatibility/functional tests, as well as extensive performance tests for both backup and restore operations |
Article ID: |
101 |
Veeam Product(s): |
|
Features and Attributes: |
|
Publication date: |
2016-08-22 |
Last modified date: |
2023-06-22 |
Product Details
Model number: Cisco UCS C240 M5 SFF Rack Server (26-drive version)
Storage Category: RAID Storage Array
Drive quantity, size, type: 24x 1.9 TB 1.9 TB 2.5 inch Enterprise Value 12G SAS SSD
Storage configuration: RAID 6 (23 drive SPAN with 1 Global Hot Spare)
Firmware version: Cisco UCS 4.2 Firmware
Connection protocol and speed: 4x25Gbe, Direct Attached Storage
Additional support: All configurations of Cisco UCS C240 M5 SFF Rack Server with specifications equivalent or greater than the above
General product family overview:
The UCS C240 M5 SFF server extends the capabilities of Cisco’s Unified Computing System portfolio in a 2U form factor with the 2nd Generation Intel Xeon Scalable Processors, 3200 MHz DDR4 memory, and the new 512GB Intel Optane Persistent Memory Modules (PMem).
Veeam Testing Configuration
Vendor recommended configuration
Vendor Settings:
- Caching used: LSI RAID controller has 2GB cache
- Read/write caching: Virtual Drive configuration through LSI RAID Controller
Strip Size – 256KB
Write Cache Policy – Write Back Good BBU
Write Back: Data is first written to the controller cache memory, and when the cache receives acknowledgment from the host, data is flushed to the disks. Data is written to the disks when the commit operation occurs at the controller cache. The controller sends a data transfer completion signal to the host when the controller cache has received all the data in a transaction.
Write Back with Battery Backup: Battery backup is used to provide data integrity protection in the event of a power failure. Battery backup is always recommended for enterprise deployments
Read Policy – ReadAhead
Always Read Ahead: The controller reads sequentially ahead of requested data and stores the additional data in cache memory, anticipating that the data will be needed soon. - Array deduplication used in testing: No
- Array compression used in testing: No
Additional resources
| FlashStack Data Protection with Veeam | Read More |
Couldn't find what you were looking for?
Please select a spelling error or a typo on this page with your mouse and press CTRL + Enter to report this mistake to us. Thank you!
Oops! Something went wrong.
Please, try again later.
Spelling error in text
Thank you!
Your feedback has been received and will be reviewed.
Oops! Something went wrong.
Please, try again later.
You have selected too large block!
Please try select less.