#1 Global Leader in Data Resilience

FAST LTA Silent Brick System

Veeam Ready - Repository
Alliance Partner:

FAST LTA

Alliance Product:

Silent Brick System

Program Category:

Veeam Ready - Repository

Category Description:

Primary backup target solutions that have been qualified as meeting or exceeding both functional and performance tests for backup and restore operations.

Article ID:

1098

Veeam Product(s):
  • Veeam Backup & Replication 12
Features and Attributes:
  • Backup Target - Disk SMB
Publication date:

2024-09-16

Last modified date:

2024-09-16

This Veeam Ready test was performed with storage having a configuration that includes SSD/Flash.  As such, this classification only applies to similar configurations in which the same amount or more SSD drives are used.  The use of non-SSD drives may negatively impact performance.
SMB write-through is supported on this platform and was used in the Veeam Ready testing. Continuous availability must be enabled for SMB share at the time of creation as it cannot be configured retrospectively. For more details about continuous availability read more at KB3124

Product Details

Model number: Silent Brick Plus (24 TB)
Storage Category: All Flash Storage
Drive quantity, size, type: 12 x 2 TB SSD
Storage configuration: RAID-Z3
Firmware version: 2.59.0.8
Connection protocol and speed: 10 GbE SMB/CIFS
Additional support: All models and configurations of FAST LTA Silent Brick Plus (24 TB) with specifications equivalent or greater than the above

General product family overview:
The Silent Brick Plus is a data container for the Silent Brick System. It occupies one slot in the Silent Brick Drive, Controller or Shelf and is equipped with 12 SSDs. 

Veeam Testing Configuration

Veeam Build Number: 12.1.2.172

Vendor recommended configuration

Vendor Settings:

  • Caching used: No
  • Does vendor solution support SMB write-through? Yes
  • How is SMB write-through enabled/disabled? 
    By default Samba sets strict sync to “yes” which then enables the windows client (Veeam) to enable / disable write through on its connection setup. Therefor write-through is enabled by the connection setup
  • Was SMB write-through enabled during the testing? Yes
  • Networking: MTU=9000
  • Multipathing / link aggregation used: SMB 3.0
  • Array deduplication used in testing: No
  • Array compression used in testing: Yes

Couldn't find what you were looking for?

Below you can submit an idea for an article.
Report a typo on this page:

Please select a spelling error or a typo on this page with your mouse and press CTRL + Enter to report this mistake to us. Thank you!
Alliance Partner content request
By submitting, you are agreeing to have your personal information managed in accordance with the terms of Veeam's Privacy Notice.
By submitting, you are agreeing to receive information about Veeam products and events and to have your personal information managed in accordance with the terms of Veeam's Privacy Notice.
This site is protected by hCaptcha and its Privacy Policy and Terms of Service apply except as noted in our Privacy Policy.
Verify your email to continue your product download
We've sent a verification code to:
  • Incorrect verification code. Please try again.
An email with a verification code was just sent to
Didn't receive the code? Click to resend in sec
Didn't receive the code? Click to resend

ty icon

Thank you!

We have received your request and our team will reach out to you shortly.

OK

error icon

Oops! Something went wrong.

Please, try again later.

Spelling error in text

This site is protected by hCaptcha and its Privacy Policy and Terms of Service apply except as noted in our Privacy Policy.
Thank you!

Thank you!

Your feedback has been received and will be reviewed.

Oops! Something went wrong.

Please, try again later.

You have selected too large block!

Please try select less.