Lenovo ThinkSystem SR630 V4

Veeam Ready Repository - Primary Target
Alliance Partner:

Lenovo

Alliance Product:

ThinkSystem

Program Category:

Veeam Ready Repository - Primary Target

Category Description:

Solutions certified as a primary backup target. Passing all compatibility/functional tests, as well as extensive performance tests for both backup and restore operations

Article ID:

2733

Veeam Product(s):
  • Veeam Backup & Replication 13
Features and Attributes:
  • Backup Target - Disk DAS
Publication date:

2026-08-24

Last modified date:

2026-08-24

This Veeam Ready test was performed with storage having a configuration that includes SSD/Flash.  As such, this classification only applies to similar configurations in which the same amount or more SSD drives are used.  The use of non-SSD drives may negatively impact performance.

Product Details

Model/version number: ThinkSystem SR630 V4
Firmware version: BMC version 1.70, UEFI version 1.40
Storage Category: RAID Storage Array
Drive quantity, size, type:

  • 2 x 480GB SSD (480GB 6Gbps M.2 SATA SSD) - OS
  • 8 x 1.92 TB SSD (NVMe 2.5) - Backup storage

Storage configuration: RAID 60
Connection protocol and speed: Direct-attached, 12 Gbit/s SAS-3
Operating system: Veeam Infrastructure Appliance
File system: XFS
Additional support: All configurations of Lenovo ThinkSystem SR630 V4with specifications equivalent or greater than the above

General product family overview:
The Lenovo ThinkSystem SR630 V4 is a 2-socket 1U rack server designed for high density and scale-out workloads in various customer segments.

Veeam Testing Configuration

Veeam Build Number: 13.0.2.29

Vendor Recommended Configuration

Vendor Settings:

  • Caching used: Yes
  • Read/write caching:
            Read Policy: Off 
            Write Policy: Protected Write Back
            Current Write Policy: Protected Write Back
            Drive Cache: Unchanged
            I/O Policy: Direct
            Access Policy: Read Write 
  • Multipathing / link aggregation used: No
  • Array deduplication used in testing: No
  • Array compression used in testing: No

Couldn't find what you were looking for?

Below you can submit an idea for an article.
Report a typo on this page:

Please select a spelling error or a typo on this page with your mouse and press CTRL + Enter to report this mistake to us. Thank you!
Alliance Partner content request
By submitting, you are agreeing to have your personal information managed in accordance with the terms of Veeam's Privacy Notice.
By submitting, you are agreeing to receive information about Veeam products and events and to have your personal information managed in accordance with the terms of Veeam's Privacy Notice.
Verify your email to continue your product download
We've sent a verification code to:
  • Incorrect verification code. Please try again.
An email with a verification code was just sent to
Didn't receive the code? Click to resend in sec
Didn't receive the code? Click to resend

ty icon

Thank you!

We have received your request and our team will reach out to you shortly.

OK

error icon

Oops! Something went wrong.

Please, try again later.

Spelling error in text

Thank you!

Thank you!

Your feedback has been received and will be reviewed.

Oops! Something went wrong.

Please, try again later.

You have selected too large block!

Please try select less.