IBM FlashSystem

Veeam Ready - Repository
Alliance Partner:

IBM

Alliance Product:

FlashSystem

Program Category:

Veeam Ready - Repository

Category Description:

Verified backup storage that supports all Veeam backup and restore features.

Article ID:

654

Veeam Product:
  • Veeam Backup & Replication 12
Features and Attributes:
  • Backup Target - Disk
Publication date:

2023-08-14

Last modified date:

2023-08-14

This Veeam Ready test was performed with storage having a configuration that includes SSD/Flash.  As such, this classification only applies to similar configurations in which the same amount or more SSD drives are used.  The use of non-SSD drives may negatively impact performance.

Product Details

Model number: IBM FlashSystem 7200, MTM: 2076-824
Storage Category: All Flash Storage
Drive quantity, size, type: IBM NVMe FlashCore Modules, 12 x 4.8TB
Storage configuration: DRAID 6
Firmware version: 8.6.0.0
Connection protocol and speed: 25 GbE iSCSI
Additional support: All models and configurations of IBM FlashSystem 7200 with specifications equivalent or greater than the above.

General product family overview:
A FlashSystem 7200 control enclosure consists of two node canisters that each run IBM Storage Virtualize software, which is part of the IBM Spectrum Storage family.
Control enclosures contain NVMe flash drives and a pair of node canisters. Each system contains up to 24 NVMe-attached IBM FlashCore® Modules or other self-encrypting NVMe-attached SSD drives. The nodes in a system operate as a single system and present a single point of control for system management and service.

Veeam Testing Configuration

Veeam Build Number: 12.0.0.1420 P20230718

Vendor recommended configuration

Vendor Settings:

  • Caching used: Caching enabled
  • Read/write caching: Read/write cache: 768GB
    For caching details please refer to chapter “5.12 Volume cache mode” in the IBM redbooks publication:  https://www.redbooks.ibm.com/redbooks/pdfs/sg248503.pdf
  • Multipathing / link aggregation used: MPIO
  • Array deduplication used in testing: No
  • Array compression used in testing: FlashCore Modules use internal compression on the drive, no further compression is done on array level.

Couldn't find what you were looking for?

Below you can submit an idea for an article.
Report a typo on this page:

Please select a spelling error or a typo on this page with your mouse and press CTRL + Enter to report this mistake to us. Thank you!
Alliance Partner content request
By submitting, you are agreeing to have your personal information managed in accordance with the terms of Veeam's Privacy Notice.
By submitting, you are agreeing to receive information about Veeam products and events and to have your personal information managed in accordance with the terms of Veeam's Privacy Notice.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Verify your email to continue your product download
We've sent a verification code to:
  • Incorrect verification code. Please try again.
An email with a verification code was just sent to
Didn't receive the code? Click to resend in sec
Didn't receive the code? Click to resend

ty icon

Thank you!

We have received your request and our team will reach out to you shortly.

OK

error icon

Oops! Something went wrong.

Please try again later.

Spelling error in text

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Thank you!

Thank you!

Your feedback has been received and will be reviewed.

Oops! Something went wrong.

Please try again later.

You have selected too large block!

Please try select less.