Release Information for NEC Storage V Series Plug-In for Veeam Backup & Replication

KB ID: 4330
Product: Veeam Backup & Replication | 10 | 11
Published: 2022-06-27
Last Modified: 2022-06-27
Get weekly article updates
By subscribing, you are agreeing to have your personal information managed in accordance with the terms of Veeam's Privacy Notice.

Cheers for trusting us with the spot in your mailbox!

Now you’re less likely to miss what’s been brewing in our knowledge base with this weekly digest

error icon

Oops! Something went wrong.

Please try again later.

Requirements

Before installing NEC V Series Plug-In v1.1.87, make sure that you are running Veeam Backup & Replication version 10.0.0.4461 or later. To check the version, open the main menu of the Veeam Backup & Replication console and select Help > About.

NEC V Series Plug-In v1.1.87 supports integration with the following storage systems:

  • V100, V300 (93-04-21-XX or later)

Follow detailed instructions on configuring the NEC Storage V Series Plug-in and the storage system in the NEC documentation [ ENG | JPN ].

Known Issues

The following is a list of known major issues for NEC Plug-In for Veeam Backup & Replication. If you experience any issue listed below, contact NEC support directly.

  • Adding NEC storage to the Veeam Backup & Replication infrastructure by Service Processor (SVP) IP is not supported but is allowed by this plug-in version. Make sure you are using one of the CTL1/CTL2 IP addresses to add the storage.
  • NEC Plug-In does not return information about volumes that are not mounted to a host. To restore from snapshots residing on such volumes, mount a volume to a host and perform a rescan in the Veeam Backup & Replication console. For details, see Rescanning Storage Systems.
  • This plug-in version does not support Freeze-only snapshots. If you want to enable VM processing using VMware snapshots, contact Veeam support to change the value of a dedicated registry key.
  • If you make any changes to host groups/iSCSI targets configuration after at least one restore operation, you must manually restart the Veeam Backup Service. The service restart will refresh the plug-in cache, and the configuration changes will be updated.
  • After deleting a snapshot, logical device (LDEV) records with the _DEL suffix may remain on storage until the subsequent automatic or manual storage rescan operation. However, such snapshots can occasionally be exported and displayed in the storage infrastructure UI as regular volumes if the storage rescan fails to purge them - in this case, they can be unexported or deleted manually.
  • The same applies to clones that are purged during rescan only if synchronization between the source snapshot and its clone is complete.
  • Snapshot deletion according to retention may fail in case synchronization between the snapshot and its clone hasn't been completed.
  • Only one volume from a GAD replication relationship should be added to a Veeam Backup & Replication instance; otherwise, SCSI UUID collisions could result in snapshots randomly created on the wrong side.
  • If jobs and rescan operations are running in parallel or at the moment when the storage system is processing other tasks, the operations may fail.
  • NEC Plug-In does not support backing up failover clusters using Veeam Agent for Microsoft Windows.
  • Veeam Backup Service restart causes subsequent Veeam Agent for Microsoft Windows job to fail. The issue occurs because the job triggers storage information caching, and it exceeds the VSS freeze timeout.
  • Ensure at least two FC ports are available on the storage; configurations with a single FC port are not supported.

Download Information

Download NEC Plug-In

Release date: 2022-06-27

MD5: 6235701aac869018d83388c8df6bf134
SHA1: 011f9c58a303da84fbfb05365534883c81deec4c
To submit feedback regarding this article, please click this link: Send Article Feedback
To report a typo on this page, highlight the typo with your mouse and press CTRL + Enter.

Spelling error in text

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Thank you!

Thank you!

Your feedback has been received and will be reviewed.

Oops! Something went wrong.

Please try again later.

KB Feedback/Suggestion

This form is only for KB Feedback/Suggestions, if you need help with the software open a support case

By submitting, you are agreeing to have your personal information managed in accordance with the terms of Veeam's Privacy Notice.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Verify your email to continue your product download
We've sent a verification code to:
  • Incorrect verification code. Please try again.
An email with a verification code was just sent to
Didn't receive the code? Click to resend in sec
Didn't receive the code? Click to resend
Thank you!

Thank you!

Your feedback has been received and will be reviewed.

error icon

Oops! Something went wrong.

Please try again later.