"Failed to convert [Not Settable] to UUID."
| KB ID: | 4694 |
| Product: |
Veeam Backup & Replication | 12.3 Veeam Plug-In for Proxmox VE |
| Published: | 2024-12-17 |
| Last Modified: | 2024-12-17 |
Get weekly article updates
Challenge
Veeam Backup & Replication task interacting with Proxmox VE host fails with:
Failed to convert [Not Settable] to UUID
Cause
This occurs when the Proxmox VE host has an empty bios UUID, or the reported bios UUID value is unparsable.
Solution
- Remove workers (if any) from the Veeam Backup & Replication configuration.
- Remove the Proxmox VE server from the Veeam Backup & Replication configuration.
- Review the Proxymox VE server's configuration and ensure that it has a BIOS UUID set correctly, per the vendor's documentation.
- Execute the following command on the Proxmox VE host to verify it reports a BIOS UUID correctly:
- Add the Proxmox VE server to Veeam Backup & Replication again, deploy workers, and proceed as normal.
More Information
Related Veeam R&D Forum thread: Failed to convert [Not Settable] to UUID
If this KB article did not resolve your issue or you need further assistance with Veeam software, please create a Veeam Support Case.
To submit feedback regarding this article, please click this link: Send Article Feedback
To report a typo on this page, highlight the typo with your mouse and press CTRL + Enter.