1-800-691-1991 | 9am - 8pm ET
EN

Issue with Data Warehouse instance collation

KB ID: 1465
Product: Veeam Management Pack for Microsoft System Center
Version: 5.7, 6.x
Published: 2011-12-29
Last Modified: 2020-08-28

Challenge

After upgrading to nworks 5.7, Data Warehouse stops running. The following error message is displayed while generating reports:

Cannot resolve the collation conflict between "SQL collation "SQL_Latin1_General_CP1_CI_AS" and "{Your_SQL_Collation_Name}" in the equal to operation.

Cause

This can happen if Operations Manager Data Warehouse was installed into an instance with unsupported collation configuration. Please refer to the Microsoft KB article below for the list of supported configurations of SQL Server for Operations Manager:

technet.microsoft.com/en-us/library/bb309428.aspx?ppud=4

NOTE: This particular error did not appear in earlier versions of nworks because nworks did not use full SCOM reporting capabilities. Since nworks v5.7, we have made a lot of changes and shipped new reporting features that use a wider range of SCOM reporting capabilities. Due to this fact, collation misconfiguration can cause errors that did not occur in previous versions of nworks.

Solution

If a SQL Server Collation other than "SQL_Latin1_General_CP1_CI_AS" is specified when installing, then OpsMgr will have to be reinstalled. Please see the Microsoft KB article below for details:

http://support.microsoft.com/kb/958979

If the collation of the database is correct, but the collation of the SQL Server instance is wrong, the database can be migrated to a SQL Server with correct collation configuration. The procedure is available through this link:

http://technet.microsoft.com/en-us/library/cc540368.aspx

More information

For more details on this matter, please contact Veeam Support at http://www.veeam.com/support.html
KB ID: 1465
Product: Veeam Management Pack for Microsoft System Center
Version: 5.7, 6.x
Published: 2011-12-29
Last Modified: 2020-08-28

Couldn't find what you were looking for?

Below you can submit an idea for a new knowledge base article.
Report a typo on this page:

Please select a spelling error or a typo on this page with your mouse and press CTRL + Enter to report this mistake to us. Thank you!

Spelling error in text

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Knowledge base content request
By submitting, you are agreeing to have your personal information managed in accordance with the terms of Veeam's Privacy Policy.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

ty icon

Thank you!

We have received your request and our team will reach out to you shortly.

OK

error icon

Oops! Something went wrong.

Please go back try again later.