#1 Global Leader in Data Resilience

Error "One or more legacy replicas are detected in configuration remove them manually and try again" during upgrade to v7

KB ID: 1806
Product: Veeam Backup & Replication
Version: 7.x
Published: 2013-08-19
Last Modified: 2024-06-13
mailbox
Get weekly article updates
By subscribing, you are agreeing to have your personal information managed in accordance with the terms of Veeam's Privacy Notice.

Cheers for trusting us with the spot in your mailbox!

Now you’re less likely to miss what’s been brewing in our knowledge base with this weekly digest

error icon

Oops! Something went wrong.

Please, try again later.

Challenge

During version 7.x Upgrade from 6.x, you receive the error "One or more legacy replicas are detected in configuration remove them manually and try again".

Legacy Replicas are any replica created by Veeam Backup prior to version 6.x.

Cause

Legacy (Created prior to Version 6 of Veeam Backup) replicas are detected in the current configuration within the Backup and Replication server.

Solution

When upgrading from Veeam Backup & Replication 6.5 to version 7.0 and the above error is presented you will need to:

  1. Cancel the v7.0 installer and open your 6.5.X installation
  2. Remove all legacy replica jobs (if present).
  3. Perform a ‘Remove from Replicas’ on any replica VMs that were created with legacy replica jobs within the ‘replicas’ pane.
  4. Once all instances of legacy replicas are removed please perform the upgrade to version 7.0.
  5. After the upgrade is complete you can follow the following KB to map to the existing replica (Procedure starts at step 9)
    https://www.veeam.com/kb1760

More Information

Further information on upgrading legacy Veeam Backup Server versions is detailed in Veeam KB https://www.veeam.com/kb1803.
To submit feedback regarding this article, please click this link: Send Article Feedback
To report a typo on this page, highlight the typo with your mouse and press CTRL + Enter.

Spelling error in text

This site is protected by hCaptcha and its Privacy Policy and Terms of Service apply except as noted in our Privacy Policy.
Thank you!

Thank you!

Your feedback has been received and will be reviewed.

Oops! Something went wrong.

Please, try again later.

You have selected too large block!

Please try select less.

KB Feedback/Suggestion

This form is only for KB Feedback/Suggestions, if you need help with the software open a support case

By submitting, you are agreeing to have your personal information managed in accordance with the terms of Veeam's Privacy Notice.
This site is protected by hCaptcha and its Privacy Policy and Terms of Service apply except as noted in our Privacy Policy.
Verify your email to continue your product download
We've sent a verification code to:
  • Incorrect verification code. Please try again.
An email with a verification code was just sent to
Didn't receive the code? Click to resend in sec
Didn't receive the code? Click to resend
Thank you!

Thank you!

Your feedback has been received and will be reviewed.

error icon

Oops! Something went wrong.

Please, try again later.