#1 Global Leader in Data Protection & Ransomware Recovery

Veeam ONE v7 R2 update

KB ID: 1841
Product: Veeam ONE
Version: 7.0
Published: 2013-12-05
Last Modified: 2020-08-13
mailbox
Get weekly article updates
By subscribing, you are agreeing to have your personal information managed in accordance with the terms of Veeam's Privacy Notice.

Cheers for trusting us with the spot in your mailbox!

Now you’re less likely to miss what’s been brewing in our knowledge base with this weekly digest

error icon

Oops! Something went wrong.

Please try again later.

Challenge

Release Notes for Veeam ONE v7 R2 update

Cause

Please confirm you are running version 7.0.0.876 prior to installing this update. You can check this under Help | About in Veeam ONE Monitor Client.
After upgrading, your build will be version 7.0.0.919.

This update should be applied to remote systems with the Veeam ONE Monitor Client, as well as the Veeam ONE server.

Solution

New Features
 
VMware
 
  • vSphere 5.5 support
  • vCloud Director 5.5 support.

Microsoft
 
  • Windows Server 2012 R2 Hyper-V and free Hyper-V Server 2012 R2 support
  • Support for Windows Server 2012 R2 and Windows 8.1 as guest virtual machines (VMs)
  • Support for System Center 2012 R2 Virtual Machine Manager (VMM)
  • Support for the installation of Veeam ONE and its components on Windows Server 2012 R2 and Windows 8.1

Resolved issues:
 
 
Monitor Client 
 
  • Refresh of the performance and alarms data takes too much time in large virtual infrastructure deployments.
  • Frequent infrastructure tree updates in large deployments makes Monitor Client slow and less responsive.

Veeam Backup & Replication Integration
 
  • Monitored Veeam backup servers are in disconnected state after upgrade to Veeam ONE v7.
  • Alarms for vPower NFS datastores cannot be suppressed.
  • Alarms for verified by a SureBackup job VMs cannot be suppressed.
  • Historical information about VM backup tasks cannot be retrieved from the backup server.
  • Veeam backup server could not be monitored by Veeam ONE server installed on non-English locales after deleting any backup job from the Veeam backup server.

Hyper-V
 
  • Snapshot size and snapshot age alarms are triggered for VMs with differencing disks.
  • Memory usage widget shows memory available counter on the summary of the Hyper-V hosts.

Email Notifications
 
  • Veeam ONE server sends email notifications for resolved warning alarms, ignoring the configured policy to notify about errors only.

Monitoring Engine
 
  • Veeam ONE Monitor service fails with the following error message “Fatal error at thread exit if FLS callback not freed” in the debug log.

Reporting Engine
 
  • Monthly report scheduling set for the last day does not work.
  • All URL triggered performance reports that have past interval as a predefined parameter display wrong reporting interval.
  • Saved performance reports using past time reporting intervals are triggered with "Date From" - "Date To" parameter. 
  • VMs with low CPU Ready metric are ignored in the Undersized VMs report.

Object Categorization
 
  • Grouping expressions with nested expressions using “IndexOf”, “<”, “>” and other operators cannot be processed.

Known issues:
 
 
Reporter
 
  • Reports generated via direct links are not displayed in Internet Explorer 11. To workaround this issue, add Veeam ONE website to trusted sites.
  • Veeam ONE website is not displayed. To workaround this issue, add Veeam ONE website to trusted sites.
  • VM Uptime report shows no data for historical time intervals after the upgrade to Veeam ONE v7 R2. This is caused by the switch to the new VM uptime monitor that improves report accuracy.

Monitor
 
  • Host disk alarms are reset to default thresholds after the upgrade. The list of affected alarms is the following: 
VMware vSphere:
  • Host disk SCSI aborts
  • Host disk bus resets
  • Host disk read latency
  • Host disk write latency
Microsoft Hyper-v server:
  • Host average disk queue length

More Information

To obtain the patch, please download it here.
To submit feedback regarding this article, please click this link: Send Article Feedback
To report a typo on this page, highlight the typo with your mouse and press CTRL + Enter.

Spelling error in text

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Thank you!

Thank you!

Your feedback has been received and will be reviewed.

Oops! Something went wrong.

Please try again later.

You have selected too large block!

Please try select less.

KB Feedback/Suggestion

This form is only for KB Feedback/Suggestions, if you need help with the software open a support case

By submitting, you are agreeing to have your personal information managed in accordance with the terms of Veeam's Privacy Notice.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Verify your email to continue your product download
We've sent a verification code to:
  • Incorrect verification code. Please try again.
An email with a verification code was just sent to
Didn't receive the code? Click to resend in sec
Didn't receive the code? Click to resend
Thank you!

Thank you!

Your feedback has been received and will be reviewed.

error icon

Oops! Something went wrong.

Please try again later.