Oops! Something went wrong.

Please try again later.

Challenge

Although everything is set up according to vCenter Connection Failover manual, the script fails to run. As a result, the following event appears in Operations Manager Event Log on Veeam Virtualizations Extension Server (VES)

"vCenterFailover.ps1 : Error: Cannot open connection. Reason: User ''NT AUTHORITY\SYSTEM' is not allowed to access the Veeam Virtualization Extensions." with id: 995

The error also triggers Veeam VMware Collector: vCenter connection failover errors and warnings Event Rule to generate a message in SCOM console.

Cause

The script is executed under SCOM Default Action Account or under account defined in Default Action Account profile for VES server.

If you use Local System account as an Action Account in most cases adding "NT AUTHORITY\SYSTEM" to Veeam Virtualization Extensions for VMware Users local group doesn't work.

Solution

Please use a domain account as SCOM Action Account for Veeam Virtualizations Extension Server.

More Information


To submit feedback regarding this article, please click this link: Send Article Feedback
To report a typo on this page, highlight the typo with your mouse and press CTRL + Enter.

Spelling error in text

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Thank you!

Thank you!

Your feedback has been received and will be reviewed.

Oops! Something went wrong.

Please try again later.

You have selected too large block!

Please try select less.

KB Feedback/Suggestion

This form is only for KB Feedback/Suggestions, if you need help with the software open a support case

By submitting, you are agreeing to have your personal information managed in accordance with the terms of Veeam's Privacy Notice.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Verify your email to continue your product download
We've sent a verification code to:
  • Incorrect verification code. Please try again.
An email with a verification code was just sent to
Didn't receive the code? Click to resend in sec
Didn't receive the code? Click to resend
Thank you!

Thank you!

Your feedback has been received and will be reviewed.

error icon

Oops! Something went wrong.

Please try again later.